Identification of Demand Sectors (DMA)
Starting with version 0.15, isolation valves can be declared on pipes or nodes, and version 0.16 introduced the ability to add flow meters using the Add Meter tool.
Choose strategic pipes in your study network where isolation valves will separate sectors, create these valves and close them with the Touch tool. Then place flow meters on larger-diameter pipes. When invoking the Obtain Demand Sectors tool, the identified DMAs appear in the Queries group, each in a different color.
QGISRed does not currently offer automatic sectorization based on specific criteria, nor much information associated with each sector. However, this represents significant progress for complex networks, where ensuring entry and exit points align only with meter locations proves challenging.