One of the most requested features in urban water distribution network simulation software is the determination of which valves must be closed to isolate a network segment around a failure point, or where works are to be carried out to extend service. This is also known as identifying the isolation polygon or shut-off area.

These operations involve isolation or shut-off valves, which are essentially on/off valves. In QGISRed, they are considered as complementary elements that do not split the pipe and therefore do not form part of the calculation model, but they do have the ability to act on the network.

The new version 0.17 of QGISRed already allows declaring a failure or intervention at a point in the network and then exploring its surroundings to determine which shut-off valves must be closed to isolate the affected area. The exploration takes into account both shut-off valves and regulation valves included in the model.

Finally, the map highlights the pipe sections that would be taken out of service as a result of the shut-off, up to the position of the closed valves, as well as the corresponding service connections if they have been previously digitised.